2 Years
PFM920I-5EUN
New product
PFM920I-5EUN
UTP CAT5e Cable
> 305 m (1000 ft)/carton UTP CAT5e, power over Ethernet, compatible with one cable
> High-purity oxygen-free copper conductor
> Customized PVC outer sheath; CE CPR Eca flame retardant class certified
> 10-year warranty
Conductor |
|||||||||||
Material |
Oxygen free copper (99.97% purity) |
||||||||||
Diameter |
0.45 mm ± 0.01 mm |
||||||||||
Insulation |
|||||||||||
Material |
HDPE |
||||||||||
Min. Average Thickness |
0.18 mm |
||||||||||
Diameter |
0.81mm±0.1mm |
||||||||||
Color (4 Pairs) |
Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown |
||||||||||
Rip Cord |
|||||||||||
Material |
Polyester |
||||||||||
Specification |
500D |
||||||||||
Sheath |
|||||||||||
Material |
PVC |
||||||||||
Min. Average Thickness |
0.5 mm |
||||||||||
Diameter |
4.7 mm ± 0.3 mm |
||||||||||
Color |
White |
||||||||||
Electrical |
|||||||||||
Max. DC Resistance of a Single Conductor |
12Ω/100 m |
||||||||||
Min. Insulation Resistance |
5000MΩ·km |
||||||||||
Max. DC Resistance Unbalance |
2% (pair intra), 4% (pairs inter) |
||||||||||
Dielectric Strength |
No breakdown with 1KV DC for 1 min |
||||||||||
Transmission |
|||||||||||
Characteristic Impedance |
100 ± 15Ω |
||||||||||
Near End Cross Talk |
≥35.30 dB/100 m@100 MHz |
||||||||||
Max. Attenuation |
24.2 dB/100 m@100 MHz |
||||||||||
Return Loss |
≥20.1 dB/100 m@100 MHz |
||||||||||
Mechanical |
|||||||||||
Tensile Strength |
Sheath≥13.5 MPa, insulation≥16 MPa |
||||||||||
Elongation at Break |
Sheath≥150%, insulation≥300% |
||||||||||
Installation Bending Radius |
>8 times of outer cable diameter |
||||||||||
Conductor Elongation at Break |
≥10% |
||||||||||
Environmental |
|||||||||||
Shrinkage of Insulation |
≤5% |
||||||||||
Color Migration Resistance of Insulation |
No migration |
||||||||||
Sheath Tensile Strength and Elongation at Break after Aging |
≥12.5 MPa, ≥100% |
||||||||||
Low Temperature Bending Test |
No cracking after the test |
||||||||||
Heat Shock Test |
No cracking after the test |
||||||||||
Operating Temperature |
–20°C to +60°C (–4°F to 140°F) |
||||||||||
Installation Temperature |
0°C to +50°C (32°F to 122°F) |
||||||||||
Storage Temperature and Humidity |
–10°C to +40°C (14°F to 104°F), <60% (RH) |
||||||||||
Security |
|||||||||||
Vertical Fire Propagation Test |
Comply with IEC 60332-1-2 |
||||||||||
Packaging |
|||||||||||
Cable Length |
305.0 m (1000.66 ft) ± 1.5 m (4.92 ft) |
||||||||||
Inner Carton Dimensions |
364.0 mm × 364.0 mm × 216.0 mm (14.33" × 14.33" × 8.50") (L × W × H) |
||||||||||
Packaging Method |
305.0 m (1000.66 ft) a carton, 45 pcs/pallet |
||||||||||
Net Weight |
≥7.0 kg (15.43 lb) |
||||||||||
Gross Weight |
≥8.0 kg (17.64 lb) |
||||||||||
Compliance |
|||||||||||
Executive Standards |
Q/DXJ 067-2019, EN50575-2014 |
||||||||||
Certification |
|||||||||||
Certification |
CPR Eca |
||||||||||
Transmission Characteristics (100 m at 20°C) (328.08 ft at 68°F) |
|||||||||||
Frequency (MHz) |
Phase delay ≤ ns |
IL ≤ dB |
TCL≥ dB﹡ |
EL TCTL ≥ dB﹡ |
NEXT ≥ dB |
PS NEXT ≥ dB |
|||||
1 |
n/s |
n/s |
50.0 |
35.0 |
n/s |
n/s |
|||||
4 |
552.0 |
4.5 |
44.0 |
23.0 |
56.3 |
53.3 |
|||||
8 |
547.0 |
6.4 |
41.0 |
16.9 |
51.8 |
48.8 |
|||||
10 |
545.0 |
7.2 |
40.0 |
15.0 |
50.3 |
47.3 |
|||||
16 |
543.0 |
9.0 |
38.0 |
10.9 |
47.2 |
44.2 |
|||||
20 |
542.0 |
10.2 |
37.0 |
9.0 |
45.8 |
42.8 |
|||||
25 |
541.0 |
11.4 |
36.0 |
7.0 |
44.3 |
41.3 |
|||||
30﹡ |
540.6 |
12.6 |
35.2 |
5.5 |
43.1 |
40.1 |
|||||
31.25 |
540.0 |
12.9 |
35.1 |
n/s |
42.9 |
39.9 |
|||||
62.5 |
539.0 |
18.7 |
32.0 |
n/s |
38.4 |
35.4 |
|||||
100 |
538.0 |
24.2 |
30.0 |
n/s |
35.3 |
32.3 |
|||||
Frequency (MHz) |
EL FEXT ≥ dB |
PS EL FEXT ≥ dB |
RL ≥ dB |
Delay skew ≤ ns |
Zc(Ω) |
||||||
1 |
n/s |
n/s |
n/s |
n/s |
n/s |
||||||
4 |
52.0 |
49.0 |
23.0 |
45.0 |
100±15 |
||||||
8 |
45.9 |
42.9 |
24.5 |
||||||||
10 |
44.0 |
41.0 |
25.0 |
||||||||
16 |
39.9 |
36.9 |
25.0 |
||||||||
20 |
38.0 |
35.0 |
25.0 |
||||||||
25 |
36.0 |
33.0 |
24.3 |
||||||||
30﹡ |
34.5 |
31.5 |
23.8 |
||||||||
31.25 |
34.1 |
31.1 |
23.6 |
||||||||
62.5 |
28.1 |
25.1 |
21.5 |
||||||||
100 |
24.0 |
21.0 |
20.1 |
||||||||
Note: Executive standard for the above parameters: Q/DXJ 067-2019"n/s"=Not Specified "﹡"=Unless otherwise customer stated the test results default to not shown in test report but comply with standard |